NOTE: If you encounter problems logging in to the remote console, be aware that some telnet programs might require you to enable their send line feed at end of line option. If the remote console does not respond to the Enter key, try setting this option in your telnet program. NOTE: You must follow the instructions in to configure the network access properly. Redirecting a Linux console In the remote console and servers with the Linux operating system, you can enable a remote login on ttyS0 by making the following changes to the BIOS Setup Utility and boot documents. NOTE: The actual steps will vary depending on your version of Linux. Using the BIOS Setup Utility, verify your system configuration by choosing one of these options based on your server model: • On ML110 G6 and DL120 G6 servers, verify the following settings: Console Redirection ◦ BIOS Serial console—Enabled ◦ Baud Rate-9600 I/O Device Configuration ◦ Embedded Serial Port Mode—BMC ◦ Embedded Serial Port—Enabled • On ML150 G6 servers, verify the following settings: Console Redirection ◦ BIOS Serial console—Enabled ◦ EMC Support (SPCR)—Enabled ◦ Serial Port Mode—9600 8,n,1 ◦ Console Type—VT100 ◦ Continue C.R.
After POST—On I/O Device Configuration ◦ Serial Port A—Enabled ◦ Base I/O address—3F8 ◦ Interrupt—IRQ 4 • On DL160 G6, DL160se G6, DL170h G6, DL170e G6, DL180 G6, SL160s G6, SL160z G6, SL165s G7, SL170z G6, and SL2x170z G6 servers, and SL165z G7 servers, verify the following settings: Remote Access Configuration NOTE: For the SL160s G6 server, the setting should be SuperIO Configuration. ◦ Serial Port Address—3F8 ◦ Serial Port IRQ—IRQ 4 ◦ Remote Access—Enabled ◦ EMS support(SPCR)—Enabled ◦ Terminal Type—VT100 Accessing the remote console through Telnet 41.
◦ Flow Control—None ◦ Redirection after BIOS POST—Always 2. In the /boot/grub/menu.lst file, append the following to the kernel startup line: console=ttyS0 115200 Comment out the line GRAPHICAL DISPLAY LINE # splashimage=(hd0,0)/grub/splash.xpm.gz 3. Add an entry to allow serial console login in /etc/inittab. For example: S0:12345:respawn:/sbin/agetty -L 115200 ttyS0 vt102 4. In /etc/securetty enable root access to ttyS0 by adding ttyS0. In /etc/sysconfig/kudzu, set kudzu to not perform serial port probing during boot. For example: SAFE=yes 6.
HP ProLiant ML100 Series Server User Guide For HP ProLiant ML110 G6 Servers and HP ProLiant ML150 G6 Servers Part Number 501528-004 February 2010 (Fourth Edition). Windows 7 Pro Oa Hp Download 2016 Torrent.
After modifying and saving the previous files, reboot the server. You can now log in to the operating system through remote console. Ringtone Sms Hp Blackberry there. After POST, in the remote console, the server prompts you with a login. Enter a valid login and use the server as you normally would. Use the ESC+Q keys to start remote console through the telnet and the ESC+( keys to exit the remote console in telnet. Microsoft Windows EMS management Windows Server 2003 provides text-based console access.